Specification:Fire alarm control panel Hong-Chang

  Explanation of Various Functions of the Machine
' Automatic Test Function
The machine can self perfrom automatic scanning test for an internal return motion or circuit break inside the switchboard, to facilitate the maintenance/ repair test motion to turn from complication into simplicity, and upgrade work performance and reliance of the mainframe.
' Storage Function
The return detection shall only go through confirmation of a fixed period of time prior to engagemement of alarm motion, to reduce the disturbance and error report situation of general circuits, and upgrade the reliability of the mainframe.
' Reserved Power Protection Device
Under the condition of power suspension, the reserved power with a power release till below DC-18V, power discharge will be automatically stopped, to extend the battery service life.
' Quality Control
The parts used for the operation panel of the Machine and internal base borad are all through CN Squality recognition; the mainframe before ex-plant shall go through a strict test to ensure service function to be normal and without an error.
' Humanistic Design
The internal base boards are all in modular design; the external line output/ input is separated by a terminal board; and due protection measures are provided to the input terminal. If an insitu wrong connection of external power into a return board, it is only required to replace the return board of the said return, without a need of dismantling external distributing circuits, to facilitate the maintenance/ inspection performance to be upgraded considerably.
' Outlook Design
High class feat resistant plastic material is applied for the return display panel of the Machine. The outlook is in streamline, simple and graceful. It is coped up with return indication plate, building unit attribte, floor level, with easily preceived return attribute.
' Other Applications
The furnction and the paging mainframe with emergency telephone mainfarme manufactured by the Company are complied into one entity with 3 machines, to attain a conformity of case frame and outlook.

  Characteristics of the Machine

Characteristics

Automatic test function
Storage function
Reserved Power protection
Qualtity control
Humanistic design
Outlook design
Simple circuit layout

Advantages

Automatic scanning test of internal return
Upgrade reliance, reduce wrong report ratio
Upgrade battery life
Upgrade reliability of mainframe
Convenient for fabrication
Easy to understand the motion of the mainframe & return panel outlook is beautiful
Apply 2 units of super large type circuit slot, to ensure easy circuit layout

Advantages in Use

Uperade work performance, time saving, labor saving
Avoid nonsense work hour consumption
Save maintenance/ repair cost, battery consumption
Reduce maintence cost, increase revenue
Upgrade work performance, time saving
Easy to facilitate a user to operate
Save circuit trimming time, labor saving

  External Dimension

Case type lron rolling
door
Circuit No 1L
H( mm) 180
W( mm) 180
D( mm) 75

Case type Wall hanging type

Circuit No 5L-10L
H( mm) 400
W( mm) 300
D( mm) 120

Case type Wall hanging type

Circuit No 15L-20L
H( mm) 580
W( mm) 300
D( mm) 120

Case type Wall hanging type

Circuit No 35L-40L
H( mm) 700
W( mm) 480
D( mm) 180

Case type Wall hanging type

Circuit No 40L-50L
H( mm) 760
W( mm) 480
D( mm) 180

Case type Wall hanging type

Circuit No 55L-60L
H( mm) 840
W( mm) 480
D( mm) 200

Case type Wall hanging type

Circuit No 65L-80L
H( mm) 1195
W( mm) 480
D( mm) 200

Case type Wall hanging type

Circuit No 85L-100L
H( mm) 1350
W( mm) 480
D( mm) 200

Case type Ground falling type

Circuit No 100L-150L
H( mm) 1800
W( mm) 580
D( mm) 260/ 360

Case type Ground falling type

Circuit No 155L-170L
H( mm) 2000
W( mm) 580
D( mm) 260/ 360

  Specification List Content of specification HC-AL

ltem Model

Power ( AC) : AC110V - 50/ 60Hz
Reserved power : DC24V
Charging Voltage/ Current : DC26V 450mAbelow
Circuit Voltage/ Current : DC24V short circuit voltage below 5V 32mA
Return external circuit resistance : Black& forth below50©
Detector installation : Differential type, fixed-temperature type smoke detector( DC24V 80uA) a smoke detector can be accessed for no more than 18 units each L
Terminal resiatance : 10K©
Quantity of indication : 1.3 times of the panel return
Regional alarm quantity : 1.3 times of the panel return
Material of machine frame : 1.6m/ m-2.0m/ mstandard material
Main stereo : Double noise above BUZZER 92db
Connection joint for transfer report : No voltage connector capacity AC150V7A
Controller of an iron rolling door : generally applicable to 100V~ 220V



Company Contact
Name:Mr. Rismiyanto [Director/CEO/General Manager]
E-mail:
Homepage:
Instant Messaging:
Mobile Number:Mobile number of Mr. Rismiyanto at Jogja
Phone Number:Phone number of Mr. Rismiyanto at Jogja
Fax Number:Fax number of Mr. Rismiyanto at Jogja
Address:Jl. Sugeng Jeroni 72 - Yogyakarta
Jogja 55251, Yogyakarta
Indonesia
24-hour Contact Center : 081 864 0850
showing 32 of 32 | Prev : COMMON BASE Hong-Chang | Next : HC-407A Fixed Temperature....


Want to build your own company website?
Please Click Here!